Home
last modified time | relevance | path

Searched hist:"10786903147 eecd96d268119a2d2c2970a64f11d" (Results 1 – 1 of 1) sorted by relevance

/honee/problems/
H A Dchannel.c10786903147eecd96d268119a2d2c2970a64f11d Fri May 13 23:45:11 UTC 2022 Jed Brown <jed@jedbrown.org> examples/fluids: fix sign and magnitude of channel flow body force

Add -body_force_scale, which can be -1 to test that a flow reversal
builds to the same steady profile with opposite sign.

I also changed the domain size (reducing Reynolds number from 4500 to
45) so flow reversal can be observed reasonably quickly when desired.